Fail to wire can be configured in the CLI using the system platform command.
Usage
system platform - Change LAN bypass on power off settings.
USAGE:
system platform display | show [working | running] [out]
system platform modify [pair1 ENABLED] [pair2 ENABLED]
WHERE:
ENABLED := { enable | disable }
EXAMPLES:
system platform modify pair1 enable
Hardware Support
Fail to wire support is dependent on hardware. The table below shows which ports and modes are supported on each hardware platform.
| Serial Number | Pair1 Ports | Pair2 Ports | Pair3 Ports | Off-mode Bypass | Run-time Bypass | Just-on Bypass |
| 00770xxx | 3 & 4 | 5 & 6 | n/a | Yes | No | No |
| 00270xxx | 1 & 2 | 3 & 4 | n/a | Yes | Yes | Yes |
| 00450xxx | 1 & 2 | 3 & 4 | 5 & 6 | Yes | Yes | Yes |
| 00460xxx | 3 & 4 | 5 & 6 | n/a | Yes | Yes | Yes |
| 00550xxx | 7 & 8 | 5 & 6 | 3 & 4 | Yes | Yes | Yes |
Modes
Off-mode Bypass: port pair passes traffic when the Ecessa device is powered off
Run-time Bypass: port pair passes traffic when the Ecessa device is powered on
Just-on Bypass: port pair passes traffic while the Ecessa device is booting and stops when boot is complete
0 Comments